| Brand Name: | WONDERY |
| Model Number: | WDL-BL -9000 |
| MOQ: | 1SET |
| Price: | TO BE NEGOTIATED |
| Delivery Time: | 35 WORKING DAYS |
| Payment Terms: | L/C, D/P, T/T, Western Union |
This equipment is specifically designed for the aluminum alloy casting industry, suitable for high-temperature transfer, holding, and in-line degassing of molten aluminum. Featuring an integrated gas-fired heating cover and degassing module with a hydraulic tilting system, it offers a rated capacity of ≥9000kg and meets the molten aluminum supply requirements of large die-casting machines or continuous casting lines. Typical applications include automotive component die casting, aluminum billet casting, and molten aluminum transfer and refining in non-ferrous metal melting workshops, particularly suited for continuous production requiring strict temperature stability and low gas content.
Rapid temperature drop causing casting defects: Molten aluminum cools quickly during long-distance transfer. Traditional open ladles lack effective insulation, leading to large temperature fluctuations and defects such as cold shuts and misruns.
High gas content affecting internal quality: Molten aluminum easily entrains air and hydrogen during transfer and pouring. Traditional ladles have no degassing function, resulting in high porosity and reduced mechanical properties.
Insufficient tilting stability: Traditional ladles rely on cranes or manual pouring with low tilting angle precision, unstable flow, and risks of splashing.
Poor durability and frequent maintenance: Ladle linings crack and spall under high-temperature aluminum erosion, resulting in short service life and frequent shutdowns for repair.
3.1 Gas-Fired Heating Cover System: Equipped with a short-flame burner with 230kW combustion power and a high-strength one-piece cast lining, effectively compensating for heat loss during transfer and maintaining stable aluminum temperature. The combustion system features automatic purging, flame monitoring, and flameout protection interlock for safe operation.
3.2 Integrated Degassing Function: The equipment integrates a degassing module to refine and degas molten aluminum during transfer, reducing gas content, improving internal casting quality, and minimizing porosity defects.
3.3 Dual Hydraulic Cylinder Synchronous Tilting Mechanism: Dual hydraulic cylinders with a mechanical synchronization valve and self-locking function. Tilting angle is precisely controlled by limit switches for smooth, controllable aluminum flow and safe operation.
3.4 High-Strength One-Piece Cast Lining: The ladle lining is formed by one-time casting with high strength and thermal shock resistance, resisting aluminum erosion and extending service life while reducing maintenance downtime.
3.5 Safety Interlock Protection System: The combustion system is equipped with fan failure interlock, abnormal air pressure interlock, and automatic gas cut-off on flameout, preventing gas leakage and accumulation for safe operation.
| Item | Specification |
|---|---|
| Carrying products | Aluminum alloy |
| Allow quantity | ≥9000 kg |
| Types of energy | Natural gas |
| Energy Interface | DN25 |
| Inlet pressure | 10~90 kPa |
| Maximum flow | 25 Nm³/h |
| Combustion power | 230 kW |
| Hydraulic station | 5.5 kW |
| Input power | 380V AC/50Hz Three-phase five-wire |
| Total power consumption | 6.5 kW |
| External dimensions (L×W×H) | 2900×3000×5220 mm (including tilting position) |
| Ladle diameter | Φ2523 mm |
5.1 Recommended Scenarios
Large die-casting machine molten aluminum supply: Large single-transfer volume requiring integrated holding and degassing
Continuous casting lines: Scenarios with strict requirements on aluminum temperature stability and gas content
Multi-variety aluminum melting workshops: Customers requiring frequent molten aluminum transfer with reduced temperature drop and secondary refining steps
5.2 Key Selection Considerations
Capacity matching: Verify whether the single-transfer weight falls within the 9000kg rated range
Gas conditions: Confirm on-site natural gas inlet pressure is within 10~90kPa with DN25 interface
Power conditions: Confirm 380V three-phase five-wire power supply with 6.5kW total power consumption reserved
Space layout: Confirm the installation area can accommodate the external dimensions and reserve tilting operation space
Q1: Does the equipment support other gas types?
A: The standard configuration is a natural gas combustion system. For LPG or city gas, please specify at the time of order; the burner and valve train will be adjusted accordingly.
Q2: Does the degassing function require additional consumables?
A: The degassing module uses inert gas (such as argon or nitrogen) for refining. Users need to provide an inert gas source; the equipment is equipped with an interface.
Q3: How is the lining repaired after damage?
A: The lining is a one-piece cast structure. Local damage can be repaired with the same castable material; for extensive damage, full re-casting is recommended. Contact after-sales for technical support.
Q4: Is the tilting angle adjustable?
A: The tilting angle is controlled by limit switches. The limit positions can be adjusted according to pouring or transfer requirements for precise stopping at different angles.